SINAMICS V20 380-480 V 3 AC – 15/+ 10 % 47-6 Poten (6SL3210-5BE32-2UV0)

2.348,95 IVA incluido

SINAMICS V20 3AC 380-480V -15/+10% 47-63HZ. Potencia Alta sobrecarga: 22KW con150% sobrecarga durante 60segundos .Potencia Baja sobrecarga: 30KW con 110% sobrecarga durante 60 segundos , sin filtro. I/O-interface: 4DI, 2DO,2AI,1AO fieldbus: USS/ MODBUS RTU con BOP incorporado, grado de protección: IP20/ UL OPEN type .Tamaño: FSE 264,5×243,5×209 (Al x An x Pr)

2 disponibles

SKU: 6SL3210-5BE32-2UV0 Categoría:

Información adicional

Number of HW-interfaces serial TTY

0

Number of analogue inputs

2

Max. output voltage

480

Supporting protocol for DeviceNet Safety

false

Supporting protocol for INTERBUS-Safety

false

Supporting protocol for PROFIsafe

false

Supporting protocol for SafetyBUS p

false

Supporting protocol for other bus systems

true

Number of HW-interfaces industrial Ethernet

0

Number of interfaces PROFINET

0

Number of phases input

3

Supporting protocol for SUCONET

false

Application in domestic- and commercial area permitted

false

Max. output frequency

550

Supporting protocol for DeviceNet

false

Number of HW-interfaces other

1

Width

245.0

Height

264.5

4-quadrant operation possible

false

Type of converter

U converter

Supporting protocol for Foundation Fieldbus

false

Number of HW-interfaces USB

0

Degree of protection (IP)

IP20

Integrated breaking resistance

true

With PC connection

false

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

1

Mains voltage

380

Supporting protocol for EtherNet/IP

false

Supporting protocol for PROFINET IO

false

Supporting protocol for AS-Interface Safety at Work

false

Supporting protocol for SERCOS

false

Nominal output current I2N

60

Max. output at quadratic load at rated output voltage

30.0

Max. output at linear load at rated output voltage

22.0

Relative symmetric net frequency tolerance

5

Relative symmetric net voltage tolerance

-15

Number of analogue outputs

1

Supporting protocol for PROFINET CBA

false

Number of digital inputs

4

Number of HW-interfaces RS-422

0

Application in industrial area permitted

true

Number of phases output

3

With optical interface

false

Supporting protocol for KNX

false

Depth

209.0

Supporting protocol for PROFIBUS

false

Supporting protocol for INTERBUS

false

Supporting protocol for LON

false

Number of HW-interfaces RS-485

1

Supporting protocol for MODBUS

true

Supporting protocol for Data-Highway

false

Supporting protocol for ASI

false

Supporting protocol for TCP/IP

false

Supporting protocol for CAN