SINAMICS V20 380-480 V 3 AC – 15/+ 10 % 47-6 Poten (6SL3210-5BE25-5UV0)

871,72 IVA incluido

SINAMICS V20 3AC 380-480V -15 / +10% 47-63HZ, Potencia nominal 5,5 kW con 150% de sobrecarga durante 60 segundos SIN FILTRO, INTERFAZ I/O: 4DI, 2DO, 2AI, 1AO, Bus de campo: USS / MODBUS RTU con BOP incorporado, GRADO DE PROTECCIÓN: IP20 / UL open type, TAMA? O: FSC 184X182X169 (Al x An x Pr)

4 disponibles

SKU: 6SL3210-5BE25-5UV0 Categoría:

Información adicional

Number of HW-interfaces serial TTY

0

Supporting protocol for AS-Interface Safety at Work

false

Mains voltage

380

Supporting protocol for DeviceNet Safety

false

Supporting protocol for INTERBUS-Safety

false

Supporting protocol for PROFIsafe

false

Supporting protocol for SafetyBUS p

false

Supporting protocol for other bus systems

true

Number of HW-interfaces industrial Ethernet

0

Number of interfaces PROFINET

0

Number of phases input

3

With optical interface

false

Application in domestic- and commercial area permitted

false

Supporting protocol for SERCOS

false

Number of analogue inputs

2

Number of HW-interfaces other

1

Width

184.0

Height

182.0

4-quadrant operation possible

false

Type of converter

U converter

Supporting protocol for Foundation Fieldbus

false

Number of HW-interfaces USB

0

Degree of protection (IP)

IP20

Integrated breaking resistance

false

With PC connection

false

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

1

Supporting protocol for PROFINET IO

false

Supporting protocol for SUCONET

false

Number of phases output

3

Supporting protocol for EtherNet/IP

false

Number of HW-interfaces RS-422

0

Nominal output current I2N

12.5

Max. output at quadratic load at rated output voltage

5.5

Max. output at linear load at rated output voltage

5.5

Relative symmetric net frequency tolerance

5

Relative symmetric net voltage tolerance

-15

Number of analogue outputs

1

Supporting protocol for PROFINET CBA

false

Number of digital inputs

4

Supporting protocol for DeviceNet

false

Application in industrial area permitted

true

Max. output frequency

550

Max. output voltage

480

Supporting protocol for KNX

false

Depth

169.0

Supporting protocol for PROFIBUS

false

Supporting protocol for INTERBUS

false

Supporting protocol for LON

false

Number of HW-interfaces RS-485

1

Supporting protocol for MODBUS

true

Supporting protocol for Data-Highway

false

Supporting protocol for ASI

false

Supporting protocol for TCP/IP

false

Supporting protocol for CAN

false