Seleccionar página

SINAMICS G120C POTENCIA ASIGNADA 11,0KW CON 150% S (6SL3210-1KE22-6UF1)

1.743,45 IVA incluido

SINAMICS G120C 3AC 380-480V +10/-20% 47-63Hz.Potencia nominal 11KW con 150% durante 3 segundos sin filtro integrado interfaz I/O: 6DI, 2DO,1AI,1AO. Safe Torque Off integrado, Bus de campo: Profinet-PN Grado de protección IP20/UL OPEN type. Tamaño: FSC 295 X 140 X 203 (Al x An x Pr) 24V externa

5 disponibles

SKU: 6SL3210-1KE22-6UF1 Categoría:

Información adicional

Supporting protocol for SERCOS

false

Supporting protocol for AS-Interface Safety at Work

false

Mains voltage

380

Supporting protocol for DeviceNet Safety

false

Supporting protocol for INTERBUS-Safety

false

Supporting protocol for PROFIsafe

true

Supporting protocol for SafetyBUS p

false

Supporting protocol for BACnet

false

Supporting protocol for other bus systems

true

Number of HW-interfaces industrial Ethernet

2

Number of interfaces PROFINET

2

Number of phases input

3

Supporting protocol for PROFINET IO

true

Number of phases output

3

Number of HW-interfaces serial TTY

1

Number of digital outputs

2

4-quadrant operation possible

false

Width

140.0

Height

295.0

With PC connection

true

Type of converter

U converter

Degree of protection (IP)

IP20

Number of HW-interfaces USB

1

Number of HW-interfaces other

6

Integrated breaking resistance

true

Supporting protocol for Foundation Fieldbus

false

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

1

With optical interface

false

Supporting protocol for SUCONET

false

Application in domestic- and commercial area permitted

true

Supporting protocol for EtherNet/IP

true

Number of HW-interfaces RS-485

0

Nominal output current I2N

26

Max. output at quadratic load at rated output voltage

11.0

Max. output at linear load at rated output voltage

7.5

Relative symmetric net frequency tolerance

5

Relative symmetric net voltage tolerance

-20

Number of analogue outputs

1

Number of analogue inputs

1

Number of digital inputs

6

Application in industrial area permitted

false

Supporting protocol for DeviceNet

false

Supporting protocol for PROFINET CBA

false

Max. output frequency

550

Max. output voltage

480

Supporting protocol for INTERBUS

false

Depth

208.0

Supporting protocol for PROFIBUS

false

Supporting protocol for TCP/IP

false

Supporting protocol for LON

false

Supporting protocol for Data-Highway

false

Supporting protocol for MODBUS

false

Supporting protocol for KNX

false

Supporting protocol for ASI

false

Number of HW-interfaces RS-422

0

Supporting protocol for CAN

false

Código Berdin

13001036

Descripción

Enlace a los datos técnicos
Enlace a la FAQ
Enlace a la descripción del producto
Enlace a la ficha técnica
Enlace a la imagen
Enlace a la información sobre REACH
Enlace a la página del producto
Enlace a los certificados
Enlace al ejemplo de aplicación
Enlace al manual
Enlace para descargar