Información adicional
Number of relay outputs | 0 |
---|---|
Supporting protocol for MODBUS | false |
Appendant operation agent (Ex ia) | false |
System accessory | true |
With display | false |
Supporting protocol for INTERBUS-Safety | false |
Supporting protocol for PROFIsafe | false |
Supporting protocol for SafetyBUS p | false |
Supporting protocol for other bus systems | true |
Radio standard Bluetooth | false |
Radio standard WLAN 802.11 | false |
Radio standard GPRS | false |
Radio standard GSM | false |
IO link master | false |
Redundancy | true |
Supporting protocol for Foundation Fieldbus | false |
Supporting protocol for SUCONET | false |
Supporting protocol for INTERBUS | false |
Supporting protocol for ASI | false |
Height | 125.0 |
Width | 120.0 |
Explosion safety category for dust | None |
Supporting protocol for SERCOS | false |
Appendant operation agent (Ex ib) | false |
Radio standard UMTS | false |
Memory size | 128.0 |
Voltage type of supply voltage | DC |
Rack-assembly possible | false |
Explosion safety category for gas | ATEX gas-ex-protection, Cat. 3G |
Wall mounting/direct mounting | false |
Rail mounting possible | true |
Additional program memory possible | false |
Suitable for safety functions | false |
Supporting protocol for AS-Interface Safety at Work | false |
Supporting protocol for PROFINET CBA | false |
SIL according to IEC 61508 | None |
Supporting protocol for KNX | false |
Number of analogue outputs | 2 |
Model | Compact |
Processing time (1K, binary operation) | 0.07 |
Number of HW-interfaces industrial Ethernet | 0 |
Number of interfaces PROFINET | 0 |
Number of HW-interfaces RS-232 | 0 |
Number of HW-interfaces RS-422 | 0 |
Number of HW-interfaces RS-485 | 1 |
Number of HW-interfaces USB | 0 |
Number of HW-interfaces parallel | 0 |
Number of analogue inputs | 4 |
Number of HW-interfaces other | 0 |
Number of digital inputs | 24 |
Type of memory | RAM |
Front build in possible | false |
Supporting protocol for EtherNet/IP | false |
Supporting protocol for Data-Highway | false |
Código Berdin | 10140650 |
Supporting protocol for PROFINET IO | false |
Supporting protocol for LON | false |
Number of digital outputs | 16 |
Supporting protocol for DeviceNet | false |
Supporting protocol for DeviceNet Safety | false |
With optical interface | false |
Number of HW-interfaces Wireless | 0 |
Supporting protocol for CAN | false |
Supply voltage DC | 19.2 |
Depth | 130.0 |
Supporting protocol for PROFIBUS | false |
Supporting protocol for TCP/IP | false |