Seleccionar página

SINAMICS G120C POTENCIA ASIGNADA 18,5KW CON 150% S (6SL3210-1KE23-8UF1)

2.724,79 IVA incluido

SINAMICS G120C 3AC 380-480V +10/-20% 47-63Hz. Potencia nominal 18,5KW con 150% durante 3 segundos sin filtro integrado interfaz I/O: 6DI, 2DO,1AI,1AO. Safe Torque Off integrado, Bus de campo: Profinet-PN Grado de protección IP20/UL OPEN type. Tamaño: FSC 295 X 140 X 203 (Al x An x Pr) 24V externa

6 disponibles

SKU: 6SL3210-1KE23-8UF1 Categoría:

Información adicional

Supporting protocol for SERCOS

false

Supporting protocol for SUCONET

false

Application in domestic- and commercial area permitted

true

Supporting protocol for DeviceNet Safety

false

Supporting protocol for INTERBUS-Safety

false

Supporting protocol for PROFIsafe

true

Supporting protocol for SafetyBUS p

false

Supporting protocol for BACnet

false

Supporting protocol for other bus systems

true

Number of HW-interfaces industrial Ethernet

2

Number of interfaces PROFINET

2

Number of phases input

3

Mains voltage

380

Number of phases output

3

Supporting protocol for DeviceNet

false

Supporting protocol for EtherNet/IP

true

With PC connection

true

Width

140.0

Height

295.0

Supporting protocol for Foundation Fieldbus

false

Type of converter

U converter

Number of HW-interfaces other

6

Number of HW-interfaces USB

1

4-quadrant operation possible

false

Integrated breaking resistance

true

Degree of protection (IP)

IP20

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

1

Max. output frequency

550

Max. output voltage

480

Number of HW-interfaces serial TTY

1

Supporting protocol for PROFINET IO

true

Number of digital outputs

2

Nominal output current I2N

38

Max. output at quadratic load at rated output voltage

18.5

Max. output at linear load at rated output voltage

15.0

Relative symmetric net frequency tolerance

5

Relative symmetric net voltage tolerance

-20

Number of analogue outputs

1

Number of analogue inputs

1

Number of digital inputs

6

Application in industrial area permitted

false

Supporting protocol for AS-Interface Safety at Work

false

Supporting protocol for PROFINET CBA

false

Number of HW-interfaces RS-485

0

With optical interface

false

Supporting protocol for TCP/IP

false

Depth

208.0

Supporting protocol for PROFIBUS

false

Number of HW-interfaces RS-422

0

Supporting protocol for LON

false

Supporting protocol for KNX

false

Supporting protocol for MODBUS

false

Supporting protocol for INTERBUS

false

Supporting protocol for ASI

false

Supporting protocol for Data-Highway

false

Supporting protocol for CAN

false

Código Berdin

13001038

Descripción

Enlace a los datos técnicos
Enlace a la FAQ
Enlace a la descripción del producto
Enlace a la ficha técnica
Enlace a la imagen
Enlace a la información sobre REACH
Enlace a la página del producto
Enlace a los certificados
Enlace al ejemplo de aplicación
Enlace al manual
Enlace para descargar